Print Page   |   Contact Us   |   Your Cart   |   Sign In   |   JOIN NFSA
Site Search
Sprinkler Systems Using Seismic Protection Distance Learning
Tell a Friend About This EventTell a Friend
 

3/17/2016 to 5/2/2016
When: March 17-May 2, 2016
Where: United States


Online registration is closed.
« Go to Upcoming Event List  

Seismic protection is a necessity for many of the buildings constructed today.  Starting with how to determine when seismic protection is necessary, this course will convey proper seismic protection for fire sprinkler systems and other water-based fire protection systems.  Lessons will cover both needed flexibility and rigidity thought the system(s).  Calculating the loads applicable to bracing will no longer be a mystery.  Following the course, participants will know their systems are protected for the next earthquake.

 

Duration:  7 weeks

 

Prerequisites: Students must have basic knowledge and familiarity of sprinkler systems installed in accordance with NFPA 13.  This includes system components, common materials, and basic spacing rules.

 

Number of Modules: 8

 

Learning Outcomes: At the conclusion of this seminar, the participant will be able to:

  1. Identify when earthquake protection is needed

  2. Calculate the applicable seismic force

  3. Describe locations in a system that need flexibility

  4. Discuss where sway braces are needed

  5. Calculate the appropriate loads for a sway brace

  6. Identify and describe components of sway braces

  7. Describe system restraints

  8. Apply seismic protection to a water-based fire protection system

FEE: Members or AHJs: $450   Non-Members: $650

Codes/Standards w/edition:

NFPA 13, 2016 Edition

ASCE 7 -16

 

Seminar Format(s):  

Lessons delivered via recorded sessions.

Live Q&A sessions.

Activities to reinforce concepts.

 

Participant Materials:  

Videos

Handouts

**Must have an NFPA 13 (2016 Edition preferred)**

 

Instructor Materials:  

NFPA 13, 2016 Edition

 

Assessment Method(s):

Quizes

Homework

Class Participation

 

Seminar Schedule: Lecture(s) available Thursday; Discussion Sessions Live Monday

March 17, 2016

Module 0: Course Introduction

Module 1: When is Earthquake Protection Needed?

March 21, 2016 Discussion

 

March 24, 2016

Module 2: What is the Force of an Earthquake?

March 28, 2016 Discussion

 

March 31, 2016

Module 3: When is Flexibility Needed in the Fire Protection System?

April 4, 2016 Discussion

 

April 7, 2016

Module 4: When is Rigidity Needed in the Fire Protection System?

Module 5: How are Loads for Sway Braces Calculated?

April 11, 2016 Discussion

 

April 14, 2016

Module 6: How are Sway Braces Configured?

April 18, 2016 Discussion

 

April 21, 2016

Module 7: When is Restraint Needed for the Fire Protection System?

April 25, 2016 Discussion

 

April 28, 2016

Module 8: Putting It All Together

May 2, 2016 Discussion

LECTURES WILL BE AVAILABLE BY 10:30am EST on THURSDAYS
DISCUSSIONS WILL BE AT 1:30pm EST on MONDAYS

FEE: Members or AHJs: $450   Non-Members: $650

more Event Calendar

10/12/2016 » 10/14/2016
Westminster, CO

 


 

"To protect lives and property from fire through the widespread acceptance of the fire sprinkler concept"-NFSA Mission Statement

Quick Links

Home     Join    Sign In    Technical Help    SQ Magazine     NFSA TV

Contact Us

Phone: (845) 878-4200      Fax: (845) 878-4215      Email Us

MD Office - 514 Progress Drive  Suite A   Linthicum Heights, MD 21090
NY Office -  40 Jon Barrett Road   Patterson, NY  12563

Membership Software Powered by YourMembership.com®  ::  Legal